home > products > adhesives, coatings & sealants > opti–tec > opt 5053 Main product index Search Home
OPT 5053

opti-tec logo
High Temperature
Epoxy Adhesive

  • Fibre optic termination adhesive
  • High temperature applications
  • Colour change upon cure
  • Low skin sensitivity
  • Long pot life
  • GR-326-CORE compliant
  • Non-cytotoxic
  • Meets
    ISO 10993-5

Description
Opti-tec 5053 is a two component, low viscosity, heat curing epoxy designed for high temperature applications. It is especially well suited to fibre optic terminating, where optical fibres are "pot and polished" into connectors or ferrules.

Product improvements
For most fibre optic terminating applications, an improved and faster cure version of OPT 5053 is recommended - please see OPT 5053-F High Temperature Fast Cure Epoxy Adhesive.

Applications

  • Fibre optic terminating
  • Endoscope manufacture and repair
  • Optoelectronics
  • High temperature, high performance bonding
  • Electronic sealing
  • Medical device assembly

Fibre Optic Termination

Features

  • OPT 5053 has high surface energy. This and its low viscosity allows it to readily wet and wick between optical fibres. It develops strong adhesion to most materials used in fibre optics and optics, including metals, ceramics, glass and most plastics.
  • OPT 5053 has excellent impact and thermal shock resistance.
  • OPT 5053's high glass transition temperature results in excellent high temperature performance and creep resistance.
  • OPT 5053 resists moisture, vapours and most chemicals. It features low outgassing and low vapour pressure, making it an ideal sealing material for electronic and optical applications.
  • OPT 5053 has a colour change upon cure, going from clear to deep translucent red.
  • OPT 5053 has been specially formulated to have very low skin sensitivity.
  • OPT 5053 has a long pot life and good handling characteristics.
  • OPT 5053 is used for Telcordia GR-326-CORE compliant assemblies (General Requirements for Singlemode Optical Connectors and Jumper Assemblies - formerly Bellcore), where its high Tg and environmental robustness allow the termination to meet the specification. Note: optimal cure schedule required.
  • OPT 5053, when cured, is considered non-cytotoxic and meets the requirements of the Elution Test, ISO 10993-5. Further ISO 10993 and USP Class VI qualification pending.
Typical Properties
Mix ratio 10:1 resin to hardener
Mix viscosity 1-2 Pa.s (1000-2000 cps)
Surface tension 42-44 mN/m
Pot life 4 hours @ 23°C
Cure schedule
Bondline temperature Time
80°C 30 mins
90°C 15 mins
100°C 10 mins
120°C 5 mins
150°C 1 min
Note: Optimal cured properties are achieved by curing for 5 minutes at a bondline temperature of 120°C. Whilst lower cure temperatures are quoted, they are not recommended for best performance.
Optimum cured properties
(5 minutes @ 120°C)
Refractive index 1.55
Glass transition temperature (Tg) >130°C
Density 1.15
Hardness, Shore D 85
Temperature range -60 to 200°C
Modulus 1 GPa
CTE 55 ppm/°C
Average between 0°C and 100°C
Adhesive properties
Lap shear
Aluminium 4000 N
Gold 4000 N
Silica 4000 N

Packaging
OPT 5053 is available in bulk kits.

Part number Description
OPT5053-550G 550g kit
1 x 500g resin, 1 x 50g hardener

Other Information

Our Technical Bulletins & Articles page has links to:


Obtain more information Obtain more information, samples or literature
Contact us Contact details and how to order
Category:
Opti-tec
Main product index Main Product Index
Search Search
Home Home

May 2005
Version 3.0


17 Station Field Industrial Estate, Banbury Road
KIDLINGTON, Oxfordshire, OX5 1JD, ENGLAND
Tel: +44 1865 842842   Fax: +44 1865 842172   info@intertronics.co.uk
Statements, technical information and recommendations contained herein are based on tests we believe to be reliable but they are not to be construed in any manner as warrantees expressed or implied. The user shall determine the suitability of the product for his intended use and the user assumes all risk and liability whatsoever in connection therewith.
© INTERTRONICS 1997, 2005