Operator Sensitisation from Fibre Optic EpoxiesIntroduction Sensitisation does not usually take place right away. It generally happens after several months or even years of breathing in the sensitiser. The symptoms can be attacks of coughing, wheezing and chest tightness, runny or stuffy nose and watery or prickly eyes. Once a person is sensitised, symptoms can occur either immediately they are exposed to the sensitiser or several hours later. If the symptoms are delayed, they are often most severe in the evenings or during the night, so operators may not realise it is work that is causing the problem. Also, once a person is sensitised, they remain sensitised indefinitely. Also, epoxy resins can cause allergic contact dermatitis, or eczema. Fibre Optic Epoxies Opti-tec 5053-F, for example, uses a different kind of diluent, a di-functional, low vapour pressure material. For this reason, it presents a much lower tendency to cause sensitisation than products which use a mono-functional, high vapour pressure diluent. Most of the hazard from epoxy sensitisation in fibre optic applications comes from vapour, and that vapour arises primarily from heating during cure. All vapours given off during heating of the epoxy should be vented away from operators; local exhaust might be considered at the mixing and dispensing area too. The vapour pressure of the diluent is a factor here, low vapour pressure being highly preferable. Hazards from handling the liquid epoxy in ambient temperatures are much less as long as simple procedures are followed. Good housekeeping would ensure that operators wear skin protection (gloves) when handling any chemical, including epoxy. Handling is reduced by purchasing and mixing the 2-part epoxy in a twinpack (no skin contact), pouring into a syringe or dispensing barrel and dispense to work wearing gloves.
Of course, some operators might be allergic or more sensitive to contact with chemicals than others. In any event, all operators should avoid any chemical contact by using the correct personal protective equipment (gloves), and practice good personal hygiene. Operators need to be adequately trained and understand the hazards. On a final note, look at hardener chemistry too: Opti-tec 5053-F's hardener does not contain acrylonitrile, a known chemical carcinogen. Conclusion |
|||||||||
|
![]() 17 Station Field Industrial Estate, Banbury Road KIDLINGTON, Oxfordshire, OX5 1JD, ENGLAND Tel: +44 1865 842842 Fax: +44 1865 842172 info@intertronics.co.uk |
||||||||